1. Introduktion

This manual provides essential instructions for the safe and efficient use, installation, maintenance, and troubleshooting of the Bradley 120-042 Rotor for Equa-Flo systems. Please read this manual thoroughly before operating the rotor to ensure proper function and longevity of the product.

2. Säkerhetsinformation

Följ alltid följande säkerhetsföreskrifter för att förhindra skador på utrustningen:

  • Ensure the rotor is correctly installed and secured in the centrifuge before operation.
  • Do not exceed the maximum rated speed of the rotor or the centrifuge.
  • Alltid balanseraamples properly to prevent vibration and potential damage.
  • Inspect the rotor for any signs of damage or wear before each use. Do not use a damaged rotor.
  • Använd lämplig personlig skyddsutrustning (PPE) såsom skyddsglasögon och handskar.
  • Håll händer och löst sittande kläder borta från rörliga delar under drift.
  • Refer to the centrifuge's main instruction manual for additional safety precautions.

3. Produkt överview

The Bradley 120-042 Rotor is designed for use with Equa-Flo centrifuge systems. It is a critical component for separating substances based on density through rapid rotation. This rotor is engineered for precision and durability in laboratory and industrial settings.

Bradley 120-042 Rotor for Equa-Flo, a silver-colored metal centrifuge rotor with multiple sample slots.

Figure 1: The Bradley 120-042 Rotor. This image displays the metallic rotor with its distinct design for holding sample tubes within an Equa-Flo centrifuge system.

4. Installationsanvisningar

  1. Uppackning: Carefully remove the rotor from its packaging. Inspect for any visible damage during shipping.
  2. Rengöring: Before first use, clean the rotor according to the maintenance instructions provided in Section 6.
  3. Installation:
    • Ensure the centrifuge spindle is clean and free of debris.
    • Carefully place the Bradley 120-042 Rotor onto the centrifuge spindle, ensuring it seats properly.
    • Secure the rotor using the appropriate locking mechanism of your Equa-Flo centrifuge. Refer to your centrifuge's manual for specific instructions.
    • Verify that the rotor is firmly attached and does not wobble.

5. Bruksanvisning

Follow these steps for safe and effective operation of the Bradley 120-042 Rotor:

  1. Massoramples: Plats sample tubes into the rotor's designated slots. Ensure all tubes are compatible with the rotor and the centrifuge.
  2. Balance Samples: Crucially, ensure that samples are balanced symmetrically across the rotor. Imbalance can lead to severe vibration, damage to the centrifuge, and potential injury. Use a balance scale if necessary.
  3. Close Centrifuge Lid: Securely close the centrifuge lid according to the centrifuge's operating instructions.
  4. Ställ in parametrar: Set the desired speed (RPM/RCF) and run time on the centrifuge control panel. Do not exceed the maximum speed specified for the rotor.
  5. Start Centrifugation: Initiate the centrifugation process. Monitor the centrifuge for unusual noises or vibrations during the initial phase of the run.
  6. Avlasta Samples: Once the run is complete and the rotor has come to a complete stop, open the centrifuge lid and carefully remove the sample rör.

6. Underhåll

Regular maintenance ensures the longevity and safe operation of your Bradley 120-042 Rotor.

  • Rengöring:
    • After each use, clean the rotor with a mild, non-corrosive detergent and distilled water.
    • Rinse thoroughly and dry completely with a soft cloth or air dry.
    • Do not use abrasive cleaners or solvents that could damage the rotor material.
  • Inspektion:
    • Periodically inspect the rotor for cracks, corrosion, pitting, or any signs of stress.
    • Kontrollera sample tube slots for deformation or damage.
    • If any damage is observed, discontinue use immediately and replace the rotor.
  • Lagring: Store the clean, dry rotor in a safe, dry environment away from direct sunlight and extreme temperatures.

7. Felsökning

This section addresses common issues that may arise during the use of the Bradley 120-042 Rotor.

ProblemMöjlig orsakLösning
Överdriven vibration/bullerUnbalanced samples; improperly seated rotor; damaged rotor.Ser tillamples are balanced. Re-seat the rotor. Inspect for damage and replace if necessary.
Rotor not reaching set speedOverloaded rotor; centrifuge motor issue; incorrect program settings.Minska sample load if applicable. Consult centrifuge manual. Verify program settings.
Rotor difficult to removeRotor stuck due to vacuum or debris.Apply gentle, even pressure. Ensure spindle is clean before installation.

If troubleshooting steps do not resolve the issue, contact Bradley customer support or a qualified service technician.

8. Specifikationer

SärdragDetalj
Modellnummer120-042
StämplaBradley
KompatibilitetEqua-Flo Centrifuge Systems
Objektets vikt10.4 uns
Produktens mått4.5 x 4.5 x 4.5 tum
Artikel Paket kvantitet1
Batterier krävsInga

9. Garanti och support

For information regarding warranty coverage, technical support, or replacement parts for your Bradley 120-042 Rotor, please contact Bradley customer service. Refer to your purchase documentation for specific warranty terms and contact details.

Tillverkare: Bradley

Artikelnummer: 120-042

© 2023 Bradley. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.