LILYTECH ZL-7918A
ZL-7918A Multifunction Automatic Temperature Humidity Controller
Bruksanvisning
1. Introduktion
The LILYTECH ZL-7918A is an advanced intelligent temperature and humidity controller designed for precise environmental management. It offers stable and reliable performance, making it ideal for applications such as incubators, climate chambers, and warehouses. This manual provides comprehensive instructions for the installation, operation, and maintenance of your ZL-7918A controller.

Figure 1: LILYTECH ZL-7918A controller with connected temperature and humidity sensors, showing the main unit and external probes.
2. Nyckelfunktioner
The ZL-7918A controller is equipped with a range of features to ensure optimal environmental control:
- Temperaturkontroll: Precise management of heating elements.
- Fuktighetskontroll: Accurate regulation of humidity levels.
- Ljuskontroll: Manages illumination cycles.
- Extra uppvärmning: Supports an additional heating output.
- Egg Turning Control: Configurable periods and durations for automatic egg turning (left and right).
- Timing Ventilation Control: Schedules ventilation cycles.
- Larmkontroll: Varningar för avvikelser från inställda parametrar.
- Kalibrering av temperatur och luftfuktighet: Allows for sensor calibration to maintain accuracy.
- Hatching Day Display: Tracks and displays the number of hatching days (up to 99 days).
3. Installation och installation
3.1 Enhetens mått och installation
The ZL-7918A controller has a device size of 160x80x95 mm. The recommended installation drilling size for mounting is 151.5x76.5 mm.
3.2 Kopplingsinstruktioner
Proper wiring is crucial for the safe and correct operation of the controller. Refer to the wiring diagram below for connections. Ensure all connections are secure and follow local electrical codes.

Bild 2: Bak view of the ZL-7918A controller, displaying the terminal block for electrical connections.

Figure 3: Detailed wiring diagram for the ZL-7918A controller, illustrating connections for power supply, sensors, and output loads.
Strömförsörjning: Connect AC100~240V 50/60Hz to terminals L and N (13 and 14).
Sensorer:
- Fuktighetssensor: Connect the Red, Yellow, Black, and Orange wires to terminals 1, 2, 3, and 4 respectively.
- Temperatursensor: Connect to terminals 5 and 6.

Figure 4: ZL-SHr05A Humidity Sensor, showing its compact design and connection points. This sensor is designed for accurate humidity measurement within a range of 0-80% RH.
Utgångskontroll: The controller provides 7 output controls. Ensure the load for heaters does not exceed 1500W, illumination does not exceed 100W, and humidity, fan, and egg turning outputs do not exceed 1A/250Vac.
- Fläkt: Terminals 15 (COM) and 16.
- Egg Turning Left: Terminals 15 (COM) and 17.
- Egg Turning Right: Terminals 15 (COM) and 18.
- Fuktighet: Terminals 15 (COM) and 19.
- Illumination (Lamp): Terminals 15 (COM) and 20.
- Auxiliary Heater (HEAT2): Terminalerna 21 och 22.
- Main Heater (HEAT1): Terminalerna 23 och 24.
4. Drift
4.1 Display överview

Bild 5: Framsidan view of the ZL-7918A controller, highlighting the digital display and control buttons for setting parameters.
The controller features a clear digital display showing current temperature (PV TEMP), set temperature (SV TEMP), current humidity (PV WET%), and set humidity (SV WET%). Indicator lights show the status of various outputs (FAN, HEAT1, HEAT2, UP, DOWN, WET, ALARM, L/R for egg turning).
4.2 Inställning av parametrar
Use the "Set" button to enter the parameter setting mode and the arrow keys (Up/Down) to navigate and adjust values. The "Enter" button confirms selections.
- Temperaturinställningsområde: 1~65℃
- Fuktighetsinställningsområde: 10~80% RH
- Egg-Turning Control:
- Period: 1~999 minutes
- Turning Time: 0~999 seconds
- Turning Times: 0~999 times
- Ventilationskontroll:
- Period: 1~999 minutes
- Ventilating Time: 0~999 seconds
- Belysningskontroll:
- Period: 1~999 minutes
- Illuminating Time: 0~999 seconds
Refer to the detailed programming guide (not included in this general manual) for specific parameter codes and advanced settings.
5. Underhåll
To ensure the longevity and accuracy of your ZL-7918A controller, follow these maintenance guidelines:
- Rengöring: Torka regelbundet av kontrollenhetens yta med en mjuk, torr trasa. Använd inte slipande rengöringsmedel eller lösningsmedel.
- Sensorvård: Keep the temperature and humidity sensors clean and free from dust or debris. Avoid exposing sensors to extreme physical shock or moisture beyond their operating limits.
- Anslutningar: Kontrollera regelbundet alla kabelanslutningar för att säkerställa att de är säkra och fria från korrosion.
- Kalibrering: If accuracy issues are suspected, perform temperature and humidity calibration as per the advanced settings guide.
6. Felsökning
This section addresses common issues you might encounter with your ZL-7918A controller. For problems not listed here, please contact customer support.
| Problem | Möjlig orsak | Lösning |
|---|---|---|
| Styrenheten slås inte på. | Ingen strömförsörjning; felaktig kabeldragning. | Check power source (AC100~240V). Verify L and N wiring connections. |
| Felaktiga temperatur-/fuktighetsavläsningar. | Dirty or faulty sensor; need for calibration. | Clean sensors. Perform temperature and humidity calibration. Replace sensor if faulty. |
| Output (e.g., heater, fan) not activating. | Incorrect settings; faulty wiring; overloaded output. | Check set parameters. Verify output wiring. Ensure load does not exceed specified limits (e.g., heaters ≤ 1500W). |
| Alarm constantly active. | Parameters outside set limits; alarm threshold too narrow. | Adjust set temperature/humidity or alarm thresholds. Ensure environmental conditions are within desired range. |
7. Tekniska specifikationer
| Parameter | Värde |
|---|---|
| Strömförsörjning | AC100~240V 50/60Hz |
| Temperatursensor | 1 (L=2M) |
| Fuktighetssensor | 1 (L=2M) |
| Fuktighetsinställningsområde | 10~80% RH |
| Temperaturinställningsområde | 1~65℃ |
| Fuktighetsvisningsområde | 0~99% RH |
| Temperaturvisningsområde | -20~80℃ |
| Humidity Measuring Accuracy | ±3% (under temperature 20~60℃) |
| Temperaturmätningsnoggrannhet | ±1 % |
| Utgångskontroll | 7 outputs (heater, aux-heater, fan, egg left-turning, egg right-turning, humidity, illumination) |
| Heater Output Load | ≤ 1500W |
| Illumination Output Load | ≤ 100W |
| Humidity, Fan, Egg Turning Output Load | ≤ 1A/250Vac |
| Hatching Day Record | Max 99 dagar |
| Driftmiljö | -10~45℃, <90%RH without dew |
| Enhetsstorlek | 160x80x95 mm |
| Installation Drilling Size | 151.5x76.5 mm |
| Material | Plast |
| Visningstyp | LCD eller LED |
8. Garantiinformation
LILYTECH products are manufactured to high quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact LILYTECH customer support directly. Keep your purchase receipt as proof of purchase for any warranty claims.
9. Kundsupport
If you require further assistance or have questions regarding your ZL-7918A controller, please contact LILYTECH customer support. Contact details can typically be found on the product packaging or the official LILYTECH webplats.
For technical inquiries, please have your product model (ZL-7918A) and a detailed description of the issue ready.
Ask a question about this manual