Pknight CR011R-3pin

Pknight CR011R-3pin ArtNet DMX Ethernet-ljusstyrenhetsgränssnitt Användarmanual

Model: CR011R-3pin

1. Introduktion

This manual provides comprehensive instructions for the setup, operation, and maintenance of your Pknight CR011R-3pin ArtNet DMX Ethernet Lighting Controller Interface. This device facilitates bi-directional conversion between Art-Net and DMX512 protocols, offering a robust solution for professional lighting control applications.

2. Produkt överview

The Pknight CR011R-3pin is a compact and durable ArtNet DMX node designed for reliable performance in various lighting environments. It features an OLED display for direct configuration and supports versatile power options.

Pknight CR011R-3pin ArtNet DMX Ethernet Lighting Controller Interface

Bild 1: Pknight CR011R-3pin ArtNet DMX Ethernet Lighting Controller Interface.

2.1 Nyckelfunktioner

  • Bi-directional ArtNet/DMX Conversion: Supports both Art-Net to DMX and DMX to Art-Net modes.
  • OLED Control System: Onboard display and buttons for direct device configuration.
  • Mångsidig kraftlösning: Compatible with 5V DC input and USB Power Delivery (PD) via USB-C.
  • Fjärrkonfiguration: Settings can be adjusted remotely using DMX Workshop software.
  • Hållbar konstruktion: Housed in a sturdy all-metal casing.

2.2 Enhetskomponenter

Pknight CR011R-3pin DMX In/Out, Ethernet, and DC5V ports

Bild 2: Bak view of the CR011R-3pin showing DMX In/Out, Ethernet, and DC5V ports.

  1. Blå LED-indikator:
    • Stays off: Standby mode, waiting for DMX (in/out).
    • Stays on (no blinking): DMX-out mode, converts ArtNet to DMX output.
    • Blinks continuously: DMX-in mode, converts DMX input to ArtNet.
  2. Female XLR Port (3-Pin): DMX input/output connection.
  3. RJ45-port (ArtNet in/ut): Ethernet connection for Art-Net data.
    • Green LED (left): Link LED.
    • Green LED (right): Activity LED (blinks fast for data activity, off for no data).
  4. Strömport (typ-C): 5V DC power input. Compatible with USB PD and third-party USB-C cables.

3. Inställning

3.1 Strömanslutning

Connect the device to a 5V DC power source using the provided USB-C cable. The device supports USB Power Delivery (PD) and can be powered by 5V adapters, PC USB ports, or power banks.

Pknight CR011R-3pin powered via USB-C

Bild 3: Powering the CR011R-3pin via its USB-C port.

3.2 Nätverksanslutning

Connect the RJ45 Ethernet port to your network switch or directly to a computer using a standard Ethernet cable. Ensure your network settings are configured to allow Art-Net communication.

3.3 DMX-anslutning

Connect your DMX lighting fixtures or DMX controller to the 3-pin XLR DMX In/Out port. The device will automatically detect the DMX signal direction based on its configured transmit mode.

4. Configuration (OLED Control System)

The CR011R-3pin features an OLED display and four function buttons for direct configuration without external software.

Pknight CR011R-3pin OLED Control System

Bild 4: OLED display and control buttons.

  1. OLED-skärm: Displays current settings and menu options.
  2. Menyknapp: Used to switch between menu options.
  3. Bakåt- eller minusknapp: Navigates backward or decreases a selected parameter.
  4. Framåt- eller plusknapp: Navigates forward or increases a selected parameter.
  5. Enter-knapp: Clicks to choose a function or parameter. Press and hold for 3 seconds to submit changes.

4.1 Remote Configuration and Naming

You can remotely configure network parameters (IP address, subnet mask, net address, subnet address, port universe) and customize the startup display text using the DMX Workshop application.

Pknight CR011R-3pin naming via DMX Workshop

Bild 5: Customizing the device name using DMX Workshop.

Pknight CR011R-3pin configuration flow

Bild 6: Diagram illustrating the configuration flow for network and Art-Net parameters.

5. Driftlägen

The CR011R-3pin supports bi-directional operation, allowing it to function as both an ArtNet to DMX converter and a DMX to ArtNet converter.

5.1 ArtNet to DMX (DMX Output Mode)

In this mode, the device receives Art-Net data over Ethernet and converts it into DMX512 signals, which are then output through the 3-pin XLR port to control DMX-compatible lighting fixtures. The blue LED indicator will stay on (no blinking).

5.2 DMX to ArtNet (DMX Input Mode)

When configured for DMX input, the device receives DMX512 signals from a DMX controller via the 3-pin XLR port and converts them into Art-Net data, which is then transmitted over Ethernet. This allows DMX consoles to control Art-Net compatible software or devices. The blue LED indicator will blink continuously.

To switch to DMX input mode, set the 'Transmit mode' to 'artnet <- dmx' via the OLED display or DMX Workshop.

Pknight CR011R-3pin DMX to ArtNet diagram

Bild 7: Diagram illustrating DMX input mode, converting DMX to ArtNet for software control.

6. Ansökningar

The Pknight CR011R-3pin is suitable for a variety of professional lighting applications, including:

  • Stage ljusstyrning
  • Pixel LED installations
  • Architectural decoration lighting
  • Fixed lighting installations
Pknight CR011R-3pin application examples

Bild 8: Visuell examples of the CR011R-3pin in various lighting applications.

7. Specifikationer

SärdragSpecifikation
ModellnummerCR011R-3pin
Objektets vikt13.4 uns
Produktens mått4.53 x 2.76 x 2.36 tum
DMX-portar1 (3-pin XLR, bi-directional)
Ethernet-portar1 (RJ45, ArtNet In/Out)
Strömingång5V DC via USB-C (supports USB PD)
KontrollgränssnittOLED display and 4 function buttons
Material för höljeAll-metal

8. Felsökning

  • Ingen DMX-utgång/ingång:
    • Verify the 'Transmit mode' setting on the device or via DMX Workshop. Ensure it matches your intended operation (ArtNet to DMX or DMX to ArtNet).
    • Check DMX cable connections and ensure they are secure.
    • Confirm that the DMX universe setting on the device matches your lighting control software. Note that some software may label the first universe as '1' while the device may internally refer to it as '0'. Adjust accordingly.
  • Ingen nätverksanslutning:
    • Ensure the Ethernet cable is properly connected and the green Link LED on the RJ45 port is illuminated.
    • Check the IP address, subnet mask, and other network parameters configured on the device and your computer/network. Art-Net typically uses a specific IP range (e.g., 2.x.x.x or 10.x.x.x) and subnet mask (e.g., 255.0.0.0).
    • If connecting directly to a computer, manually configure your computer's network adapter to be in the same IP range as the device.
    • Confirm that your network allows UDP traffic on Art-Net's default port (6454).
  • Enheten slås inte på:
    • Ensure the USB-C power cable is securely connected to both the device and a functional 5V power source.
    • Prova en annan USB-C-kabel och nätadapter för att utesluta felaktiga tillbehör.

9. Underhåll

To ensure the longevity and optimal performance of your Pknight CR011R-3pin, follow these maintenance guidelines:

  • Rengöring: Använd en mjuk, torr trasa för att rengöra enhetens utsida. Undvik att använda flytande rengöringsmedel eller lösningsmedel, eftersom de kan skada ytan eller de interna komponenterna.
  • Lagring: När den inte används, förvara enheten på en sval, torr plats borta från direkt solljus och extrema temperaturer.
  • Kabelhantering: Ensure all cables are routed properly to prevent strain on the connectors and accidental disconnections.
  • Firmware -uppdateringar: Kontrollera regelbundet tillverkarens website for any available firmware updates to ensure the device has the latest features and bug fixes.

10. Garanti och support

Pknight products are designed for reliability and performance. For specific warranty information, please refer to the warranty card included with your product or visit the official Pknight website. If you encounter any issues or require technical assistance, please contact Pknight customer support through their official channels.