FireAngel FA6812

FireAngel FA6812 Digital LCD Carbon Monoxide Detector User Manual

Modell: FA6812

1. Introduktion

The FireAngel FA6812 is a digital carbon monoxide (CO) detector designed to provide reliable protection against the dangers of CO gas. Carbon monoxide is an invisible, odorless, and potentially fatal gas. This device features an electrochemical sensor with a 10-year lifespan and an LCD screen for clear display of CO levels and device status. Early detection and warning are crucial for preventing CO poisoning.

FireAngel FA6812 Carbon Monoxide Detector on a kitchen counter

Figure 1: FireAngel FA6812 Carbon Monoxide Detector

This manual will guide you through the installation, operation, and maintenance of your FA6812 detector to ensure optimal performance and safety.

2. Installation och installation

2.1 Paketets innehåll

  • FireAngel FA6812 Kolmonoxidlarm
  • 2 x AA batterier
  • Monteringsskruvar och väggpluggar
  • Användarmanual

2.2 Batteriinstallation

The FA6812 detector requires 2 AA batteries for operation. These are included in the package. To install the batteries:

  1. Leta reda på batterifacket på baksidan av enheten.
  2. Öppna batterifackets lock.
  3. Sätt i de 2 AA-batterierna och se till att polerna är rättvända (+ och -).
  4. Stäng batterifacket ordentligt.

The device will emit a short beep and the LCD will activate, indicating successful battery installation.

2.3 Placeringsrekommendationer

For optimal CO detection, consider the following placement guidelines:

  • General Placement: Install the detector at mid-height in a room, as carbon monoxide mixes evenly with air. Avoid placing it near the floor or ceiling.
  • Proximity to Appliances: Place the detector at least 3 meters (10 feet) away from any fuel-burning appliances (e.g., boilers, gas stoves, fireplaces).
  • Sleeping Areas: For maximum protection, install a detector in or near sleeping areas.
  • Undvik hinder: Ensure the detector is not obstructed by furniture, curtains, or other objects that could block the sensor.
  • Miljöfaktorer: Avoid placing the detector in direct sunlight, in areas of high humidity (e.g., bathrooms), or near ventilation openings.

2.4 Monteringsalternativ

The FA6812 can be used freestanding or wall-mounted.

  • Fristående: The compact and portable design allows the unit to be placed on a flat surface, such as a shelf or table.
  • Väggmontering: Use the integrated mounting bracket and provided screws to securely attach the detector to a wall. Ensure the mounting location adheres to the placement recommendations above.
FireAngel FA6812 Carbon Monoxide Detector with packaging showing 10-year sensor and replaceable AA batteries

Figur 2: Produkt överview med viktiga funktioner

3. Drift

3.1 LCD Display Indications

The digital LCD screen provides real-time information about the detector's status:

  • Standbyläge: Displays the current CO level in parts per million (ppm). If no CO is detected, it will show '0 ppm'.
  • CO-larm: When dangerous CO levels are detected, the screen will display the CO concentration in ppm, accompanied by an audible alarm and a flashing red light.
  • "AL" (Alarm in Absence): If a CO alarm triggers while you are away, the device will enter "Alarm in Absence" mode. The screen will display "AL", and the unit will beep every 40 seconds with a red flashing light until deactivated.
  • Batteristatus: An icon indicates the battery level. A flashing orange "!" and continuous beep signify low batteries.
  • "EOL" (End of Life): This indicator signals that the device has reached the end of its 10-year operational life and needs replacement.
FireAngel FA6812 LCD screen showing various functions and indicators

Figure 3: Multifunction LCD Screen

3.2 Larmaktivering

In the event of CO detection, the FA6812 will:

  • Emit four loud beeps (85 dB(A) at 3m minimum).
  • Flash a red LED light.
  • Display the CO concentration in ppm on the LCD screen.

Om larmet ljuder:

  1. Immediately move to fresh air outdoors or open all doors and windows.
  2. Gör en räkning för att kontrollera att alla personer är medräknade.
  3. Gå inte in i lokalen igen förrän larmet har upphört och området har ventilerats ordentligt.
  4. Sök läkarvård om du upplever symtom på CO-förgiftning (huvudvärk, illamående, yrsel).
  5. Contact the appropriate emergency services or a qualified technician to investigate the source of the CO.

3.3 Sleep Easy™ Function

The Sleep Easy™ function allows you to temporarily silence the low battery warning for 8 hours. To activate:

  • Press and hold the test button when the low battery warning sounds.

During this period, the orange indicator light will continue to flash, and the device remains fully functional for CO detection. This feature is designed for convenience, but batteries should be replaced as soon as possible.

FireAngel FA6812 showing advanced functions like 'Alarm in your absence' and 'Sleep Easy'

Figur 4: Avancerade funktioner

4. Underhåll

4.1 Regelbunden testning

It is recommended to test your CO detector monthly to ensure it is functioning correctly. To perform a test:

  • Press and hold the 'TEST' button on the front of the unit.
  • The alarm will sound, and the red LED will flash, indicating the alarm is working.
  • Släpp knappen för att stoppa testet.

4.2 Batteribyte

When the batteries are low, the detector will indicate this with a flashing orange "!" on the LCD and a continuous beep. Replace the batteries immediately to maintain continuous protection. Refer to section 2.2 for battery installation instructions.

4.3 End of Life (EOL) Indication

The FA6812 has a 10-year lifespan. When the device reaches its end of life, the LCD will display "EOL". At this point, the detector should be replaced with a new unit to ensure continued safety.

4.4 Rengöring

Dust and debris can affect the detector's performance. Gently clean the exterior of the unit with a soft, damp cloth. Do not use cleaning agents or solvents, as these can damage the sensor or casing. Do not paint the detector.

5. Felsökning

ProblemMöjlig orsakLösning
Alarm sounds and LCD shows CO levelKolmonoxid upptäcktFollow alarm activation procedures (Section 3.2). Evacuate, ventilate, seek medical help if needed, and identify CO source.
Flashing orange "!" and continuous beepVarning för lågt batteriReplace batteries immediately (Section 4.2). Use Sleep Easy™ function if temporary silence is needed.
LCD displays "AL" and beeps every 40 secondsAlarm in Absence triggeredA CO alarm occurred while you were away. Investigate potential CO sources and ventilate the area.
LCD displays "EOL"Slutet på produktens livslängdReplace the detector with a new unit. The sensor is no longer reliable after 10 years.
No display or unit unresponsiveNo batteries, incorrect battery installation, or faulty unitCheck battery installation and polarity. Replace batteries. If still unresponsive, the unit may be faulty and require replacement.

6. Specifikationer

SärdragSpecifikation
ModellnummerFA6812-EUX10
SensortypElektro
Sensorns livslängd10 år
Strömkälla2 x AA alkaliska batterier (ingår)
Larmljudstyrka85 dB(A) at 3 meters (minimum)
VisaDigital LCD
Mått (L x B x H)120 x 73 x 35.5 mm
Vikt145 gram
Driftstemperatur0°C till 40°C
Driftfuktighet30 % till 90 % RH (icke-kondenserande)
EfterlevnadBS EN 50291-1:2018, BS EN 50291-2:2019, CE Marked
UPC816317006860

7. Garanti och support

7.1 Garantiinformation

The FireAngel FA6812 Carbon Monoxide Detector is designed for long-term reliability. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official FireAngel webwebbplats. Garantiperioderna kan variera beroende på region.

7.2 Kundsupport

If you have any questions, require technical assistance, or need to report an issue with your FireAngel FA6812 detector, please contact FireAngel customer support. Contact details can typically be found on the product packaging or the official FireAngel webwebbplats (www.fireangeltech.com).

© 2026 FireAngel. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.