Användarhandbok för AiM LCU1S Lambda-styrenhet

AiM LCU1S Lambda Controller User Guide

AiM-logotyp

AiM LCU1S Lambda-regulator

AiM-LCU1S-Lambda-Controller-product

Produktinformation

 Introduktion

  • LCU1S is the new smaller, lighter and faster AiM Lambda Controller expansion supported by all the last car-bike AiM devices.
    Observera: the only systems that does not support LCU1S are MXL, MXL2 and MyChron.
  • Med LCU1S kan du perfekt finjustera motorns förgasare samt förbättra motorns prestanda.
  • LCU1S använder en Bosch LSU4.9-sond som sparar den ursprungliga kalibreringen under sensorns livslängd och håller i mer än 100 000 km på en standardbil.

Available kits, optionals and spare parts

Tillgängliga LCU1S-kit är:

  • LCU1S complete kit; part number: X08LCU1SAC090
    • LCU1S
    • Bosch LSU 4.9 Lambda probe
    • Thread iron ring for installation

LCU1S kit without Lambda probe; part number: X08LCU1SAC0

  • LCU1S

Optionals7 and spare parts:

  • Bosch LSU 4.9 Lambda probe X05LSU490
  • Thread iron ring for installation LBS552680
  • 50cm AiM CAN cable V02552690
  • 100cm AiM CAN cable V02552700
  • 200cm AiM CAN cable V02552720
  • 400cm AiM CAN cable V02551070

Configuring LCU1S

LCU1S kan endast konfigureras med hjälp av AiM RaceStudio 3-programvaran som du kan ladda ner gratis från AiM. webplats på www.aim-sportline.com download software/firmware area.
LCU1S is an expansion that is to be loaded on AiM device configuration so first of all run the software and select the configuration where to load LCUS1S on or create a new one as shown here below. To create a new configuration:

  • Press “New Configuration” (1)
  • Select the device you are configuring (Solo 2 DL v2 in the example below 2)
  • Tryck på "OK" (3)

AiM-LCU1S-Lambda-Controller- (1)

The software enters “Channels” tab.

AiM-LCU1S-Lambda-Controller- (2)

To load LCU1S activate “CAN Expansions” (1) tab as shown here below and follow these steps:

  • Press “New Expansion” (2)
  • Select LCU1S (3)
  • Tryck på "OK" (4)

AiM-LCU1S-Lambda-Controller- (3)

Once the expansion added, the software enters the related tab (0LC1S). Here it is possible to:

  • Get the serial number of LCU1S or fill it in manually (1); please note: to get the serial number from the connected LCU1S it is necessary to power it and connect the master device LCU1S is connected to your PC via Wi-Fi (or via USB). Please refer to the user manual of each logger to know how to manage Wi-Fi connection;
    • select the multiplier to calculate AFR from Lambda value
    • manage custom values through the dedicated panel that is prompted clicking the proper button
  • As far as the channel table (2) is concerned, clicking on each channel it is possible to set samplingfrekvens, måttenhet och visningsprecision.

AiM-LCU1S-Lambda-Controller- (4)

How to get the serial number of a connected LCU1S

To get the serial number of the connected LCU1S ensure that LCU1S is powered and connect the master logger to the PC. To do so:

  • click the Wi-Fi icon top right of the software view (or plug the USB cable of the logger in the PC USB port)
  • Select the logger to connect via Wi-Fi and press “Connect”.
  • AiM-LCU1S-Lambda-Controller- (5) Once the logger connected press “Get Expansion Serial Number” as shown here below
  • A panel is prompted: select the connected expansion to configure and press “OK”AiM-LCU1S-Lambda-Controller- (6)
  • the software comes back to “CAN Expansions” tab and shows LCU1S Serial number.AiM-LCU1S-Lambda-Controller- (7)

Online view och firmwareuppdatering

Once LCU1S connected and identified it is suggested to complete, save and transmit the configuration to the logger. This procedure changes according to the logger that is being configured.
Now it is possible to enter online view and check LCU1S values. To do so:

  • enter “Configurations” view
  • Press the logger you are configuring as shown here below.

AiM-LCU1S-Lambda-Controller- (8)

Programvaran går online view:

  • Activate “Firmware” tab
  • De view visar loggern och dess expansioner till höger om view som visas nedan.

AiM-LCU1S-Lambda-Controller- (11)

To update both logger and expansions firmware:

  • click the related button top right of the view
  • AiM-LCU1S-Lambda-Controller- (12)the software enters firmware update view where it is possible to download and install the firmware as for any AiM device.

AiM-LCU1S-Lambda-Controller- (13)

Tekniska specifikationer och ritningar

LCU1S technical specifications are

  • Sensor compatibility Bosch LSU4.
  • Strömförsörjning voltage 9-15V
  • Power supply current 50mA ÷ sensor heater typical current 750 mA up to 2A on cold sensor
  • Reaction time Less than 10msec
  • Material Latigloss 57
  • Mått 43.4x30x18.4 mm
  • Vikt 70g
  • Vattentät IP67

LCU1S Dimensions in mm [inches]

AiM-LCU1S-Lambda-Controller- (9)

LCU1S Pinout

AiM-LCU1S-Lambda-Controller- (10)

Vanliga frågor

Which AiM devices are not compatible with LCU1S?

MXL, MXL2, and MyChron are the systems that do not support LCU1S.

What is the lifespan of the Bosch LSU4.9 probe?

The probe lasts for more than 100,000 km on a stock car.

Dokument/resurser

PDF thumbnailLCU1S Lambdaregulator
User Guide · X08LCU1SAC090, X08LCU1SAC0, X05LSU490, LCU1S Lambda Controller, LCU1S, Lambda Controller, Controller

Referenser

Ställa en fråga

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ställa en fråga

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.